2023/05/31 by Rodrigo A. González, González, Rodrigo A., Cristian R. Rojas +5
Engineering · #Advanced Control Systems Optimization #Control Systems and Identification #FOS: Electrical engineering #Fault Detection and Control Systems #Systems and Control (eess.SY) #electronic engineering #information engineering
paper · pdf · doi:10.48550/arxiv.2305.19676
openalex publication_date 2023/05/31 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28
The Refined Instrumental Variable method for discrete-time systems (RIV) and its variant for continuous-time systems (RIVC) are popular methods for the identification of linear systems in open-loop. The continuous-time equivalent of the transfer function estimate given by the RIV method is commonly used as an initialization point for the RIVC estimator. In this paper, we prove that these estimators share the same converging points for finite sample size when the continuous-time model has relative degree zero or one. This relation does not hold for higher relative degrees. Then, we propose a modification of the RIV method whose continuous-time equivalent is equal to the RIVC estimator for any non-negative relative degree. The implications of the theoretical results are illustrated via a simulation example.