vix.ing · top · new · best · stats · spec

Test Results of PIP2IT MEBT Vacuum Protection System

2019/12/05 by A. Chen, Chen, A., R. Andrews +11
Engineering · #Accelerator Physics (physics.acc-ph) #FOS: Physical sciences #Particle Accelerators and Free-Electron Lasers #Particle accelerators and beam dynamics #Superconducting Materials and Applications

paper · pdf · doi:10.48550/arxiv.1912.02897

openalex publication_date 2019/12/05 · openalex created_date 2025/10/10 · openalex updated_date 2026/08/01

Abstract

The central part of PIP-II program of upgrades pro-posed for the Fermilab injection complex is an 800 MeV, 2 mA, CW-compatible SRF linac. Acceleration in super-conducting cavities begins from a low energy of 2.1 MeV, so that the first cryomodule, Half Wave Resonator (HWR) borders the warm Medium Beam Transport (MEBT) line. To minimize the amount of gas that may enter the SRF linac in a case if a vacuum failure occurs in the warm front end, a vacuum protection system is envisioned to be used in the PIP-II MEBT. It features a fast closing valve with two sensors and a differential pumping insert. The system prototype was installed in the PIP-II Injector Test (PIP2IT) accelerator and successfully tested in several modes modelling the vacuum failures. The report presents the design of the vacuum protection system and results of its tests.