vix.ing · top · new · best · stats · spec

Measurement of SiPM Dark Currents and Annealing Recovery for Fluences Expected in ePIC Calorimeters at the Electron-Ion Collider

2025/03/18 by Jiajun Huang, Sean Preins, Huang, Jiajun +9 · 1 citation
Physics and Astronomy · #FOS: Physical sciences #High Energy Physics - Experiment (hep-ex) #Instrumentation and Detectors (physics.ins-det) #Nuclear Experiment (nucl-ex) #Particle Detector Development and Performance #Radiation Detection and Scintillator Technologies #Superconducting and THz Device Technology

paper · pdf · doi:10.48550/arxiv.2503.14622

openalex publication_date 2025/03/18 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28

Abstract

Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is essential for accurate simulations, detector design, and effective operational strategies. In this study, we evaluate radiation damage for the specific SiPM models chosen for ePIC across the complete fluence range anticipated at the EIC, 108 to 1012 1-MeV neq/cm2 per year, depending on the calorimeter location. The SiPMs were irradiated using a 64 MeV proton beam provided by the University of California, Davis 76" Cyclotron. We measured the SiPM dark-current as a function of fluence and bias voltage and investigated the effectiveness of high-temperature annealing to recover radiation damage. These results provide a comprehensive reference for the design, simulation, and operational planning of all ePIC calorimeter systems.

Cited by

Related