vix.ing · top · new · best · stats · spec

Precision measurements on the 138Ba+ 6s2S1/2-5d2D5/2 clock transition

2019/06/30 by Kyle J. Arnold, Rattakorn Kaewuam, Sapam R. Chanu +3 · 1 citation
Physics and Astronomy · #physics.atom-ph #quant-ph

paper · pdf · doi:10.1103/physrevlett.124.193001

published as Phys. Rev. Lett. 124, 193001 (2020) · 5 pages, 4 figures, plus 3 page Supplemental Material

arxiv created 2020/03/12 · arxiv updated 2020/05/20

Abstract

Measurement of the 138Ba+ 2S1/2 - 2D5/2 clock transition frequency and D5/2 Landé gJ factor are reported. The clock transition frequency νBa+=170 126 432 449 333.31±(0.39)stat±(0.29)sys Hz, is obtained with accuracy limited by the frequency calibration of the maser used as a reference oscillator. The Landé gJ-factor for the 2D5/2 level is determined to be gD=1.200 367 39(24), which is a 30-fold improvement on previous measurements. The g-factor measurements are corrected for an ac-magnetic field from trap-drive-induced currents in the electrodes, and data taken over a range of magnetic fields underscores the importance of accounting for this systematic.

Cited by