2002/04/17 by V. Ammosov, V. V. Ammosov, Ammosov, V. +16
Physics and Astronomy · #Atomic and Subatomic Physics Research #FOS: Physical sciences #High Energy Physics - Experiment (hep-ex) #Particle Detector Development and Performance #Radiation Detection and Scintillator Technologies #hep-ex
paper · pdf · doi:10.48550/arxiv.hep-ex/0204022
18 pages, 13 figures
arxiv created 2002/04/17 · openalex publication_date 2002/04/17 · arxiv updated 2009/11/30 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28
A four-gap glass RPC with 0.3mm gap size was tested with hadron beam as a time-of-flight detector having a time resolution of ~ 100ps. A thickness of the detector together with front-end electronics is ~ 12mm. Results on time resolution dependently on a pad size are presented. This paper contains first result on the timing RPC (with ~ 100ps resolution) having a strip read-out. Study has been done within the HARP experiment (CERN-PS214) R&D work. A obtaned data can be useful if a design of a large area thin timing detector has to be done.