vix.ing · top · new · best · stats · spec

Noise Equivalent Counts Based Emission Image Reconstruction Algorithm of Tomographic Gamma Scanning

2014/04/17 by Ke Wang, Wang, Ke, Zheng Li +5
Physics and Astronomy · #FOS: Physical sciences #Nuclear Experiment (nucl-ex) #nucl-ex

paper · pdf · doi:10.48550/arxiv.1404.4510

9 pages, 6 figures

arxiv created 2014/04/17 · arxiv updated 2014/04/18

Abstract

Tomographic Gamma Scanning (TGS) is a technique used to assay the nuclide distribution and radioactivity in nuclear waste drums. Both transmission and emission scans are performed in TGS and the transmission image is used for the attenuation correction in emission reconstructions. The error of the transmission image, which is not considered by the existing reconstruction algorithms, negatively affects the final results. An emission reconstruction method based on Noise Equivalent Counts (NEC) is presented. Noises from the attenuation image are concentrated to the projection data to apply the NEC Maximum-Likelihood Expectation-Maximization algorithm. Experiments are performed to verify the effectiveness of the proposed method.

Related