vix.ing · top · new · best · stats · spec

デイヴィッド・ミラーのグローバルな正義への懐疑論--グローバルな正義の課題設定のために

2007/03/01 by Darwish Al-Azmi, A I. Abu-Shady, A. I. Abu-Shady +4 · 1 citation
Health Professions · Earth and Planetary Sciences · #Radioactivity and Radon Measurements #Radioactivity and Radon Measurements #Earthquake Detection and Analysis

paper · doi:10.1097/01.hp.0000281177.42452.8f

Abstract

Indoor radon measurements were carried out in 300 dwellings in Kuwait using duplicate sets of charcoal detectors. Measurements were made at three different locations in the dwellings: living rooms, bedrooms, and basements. The results show that the radon concentration in the dwellings of Kuwait was found to vary in the range of 4.0-241.8 Bq m(-3) with a mean value of 32.8 Bq m(-3), and most values are confined within the range of 10-50 Bq m(-3) for all locations with few cases above the value of 100 Bq m(-3). Overall results show that the indoor radon concentration levels in Kuwait are relatively low, which is attributed to the use of air conditioning in summer and possible natural ventilation in winter. The radon concentration in basements was found to be relatively higher when compared to other rooms of the dwellings.

Cited by

Related