vix.ing · top · new · best · stats · spec

Cosmic-ray tests of the DØ preshower detector

2000/07/14 by P. Baringer, A. Bross, V. Buescher +30 · 2 citations
Physics and Astronomy · #Dark Matter and Cosmic Phenomena #Particle Detector Development and Performance #Superconducting and THz Device Technology #hep-ex

paper · pdf · doi:10.1016/s0168-9002(01)00781-1

published as Nucl.Instrum.Meth.A469:295-310,2001 · 27 pages, 24 figures, submitted to NIM A

arxiv created 2000/07/14 · openalex publication_date 2001/08/01 · arxiv updated 2009/11/30 · openalex created_date 2016/06/24 · openalex updated_date 2026/07/28

Abstract

The D0 preshower detector consists of scintillator strips with embedded wavelength-shifting fibers, and a readout using Visible Light Photon Counters. The response to minimum ionizing particles has been tested with cosmic ray muons. We report results on the gain calibration and light-yield distributions. The spatial resolution is investigated taking into account the light sharing between strips, the effects of multiple scattering and various systematic uncertainties. The detection efficiency and noise contamination are also investigated.