vix.ing · top · new · best · stats · spec

Application of Model Derived Charge Transfer Inefficiency Corrections to STIS Spectroscopic CCD Data

2003/10/24 by Paul Bristow, Bristow, Paul
Engineering · Physics and Astronomy · #Astrophysics (astro-ph) #CCD and CMOS Imaging Sensors #Calibration and Measurement Techniques #FOS: Physical sciences #Stellar, planetary, and galactic studies #astro-ph

paper · pdf · doi:10.48550/arxiv.astro-ph/0310710

PDF file, 13pages, 6 figures

arxiv created 2003/10/24 · openalex publication_date 2003/10/24 · arxiv updated 2009/12/01 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28

Abstract

The ST-ECF Calibration Enhancement effort for the Space Telescope Imaging Spectrograph (STIS) aims to improve data calibration via the application of physical modelling techniques. As part of this effort we have developed a model of the STIS CCD readout process. The model itself is described in some detail in earlier ISRs. Here we consider the application to STIS spectroscopic data. We find good agreement between the simulation derived corrections and empirical corrections for a range of background and source levels. Moreover we find that, where the two differ, because only the simulation properly accounts for the charge distribution in the array.