The Tracking performance for the IDEA drift chamber

2022/11/22 by W. Elmetenawee, Elmetenawee, Walaa, G. Chiarello +23 · 1 citation
Physics and Astronomy · #Dark Matter and Cosmic Phenomena #FOS: Physical sciences #Instrumentation and Detectors (physics.ins-det) #Particle Detector Development and Performance #Particle physics theoretical and experimental studies

paper · pdf · doi:10.48550/arxiv.2211.12568

openalex publication_date 2022/11/22 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28

Abstract

The IDEA detector concept for a future e+e- collider adopts an ultra-low mass drift chamber as a central tracking system. The He-based ultra-low mass drift chamber is designed to provide efficient tracking, a high-precision momentum measurement, and excellent particle identification by exploiting the cluster counting technique. This paper describes the expected tracking performance, obtained with full and fast simulation, for track reconstruction on detailed simulated physics events. Moreover, the details of the construction parameters of the drift chamber, including the inspection of new material for the wires, new techniques for soldering the wires, the development of an improved schema for the drift cell, and the choice of a gas mixture, will be described.

Cited by