2018/01/16 by K. I. Deshko, Deshko, K. I., V. A. Chernikov +1
Engineering · Physics and Astronomy · #FOS: Physical sciences #Induction Heating and Inverter Technology #Instrumentation and Detectors (physics.ins-det) #Plasma Diagnostics and Applications #Vacuum and Plasma Arcs
paper · pdf · doi:10.48550/arxiv.1803.10263
openalex publication_date 2018/01/16 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28
The work of the miniature magneto-plasma compressor with the low-voltage power supply system was studied experimentally and the current and discharge voltage drop were measured. It was found that the voltage drop (a few tens of volts) remains practically constant during discharge. Performed electrical analysis allowed to determine the power efficiency of the supply system depending on the initial capacitor voltage, the discharge voltage and circuit parameters (capacitance, inductance, resistance).