2015/12/15 by Kopylov, A. V., Orekhov, I. V., Petukhov, V. V.
#FOS: Physical sciences #High Energy Physics - Experiment (hep-ex) #Instrumentation and Detectors (physics.ins-det)
paper · doi:10.48550/arxiv.1512.04675
We report on a new technique of a Multi-Cathode Counter (MCC) developed to search for hidden photon (HP) cold dark matter (CDM) with a mass from 5 to 500 eV. The method suggested in the assumption that hidden photons of the mass greater than a work function of the metal, the cathode of the counter is fabricated induce emission of single electrons from a cathode. Three configurations of the same counter are used to measure the count rates R1, R2 and R3 of the single electron events during several weeks. As a measure of the effect from HP the difference R1-(R2-D3/D2xR3) has been used. Some preliminary results have been obtained on a first try to search for HP with a mass from 5 to 500 eV. The upper limit for mixing parameter X has been set on the level of 3.3x10-10 for hidden photon mass from 9 to 100 eV. In our plans is to refine the procedure of data treatment and to continue the measurements to collect more data.