#1′-biphenyl]-2-ol #2-Hydroxybiphenyl #2-biphenylol #2-hydroxybiphenyl #Arbeitsplatzmessung #Biphenyl-2-ol #Dampf-Partikel-Gemisch #E 231 #Gefahrstoffe #HPLC-DAD #Hochleistungsflüssigchromatographie #Luftanalysen #OPP #Orthophenylphenol #Quarzfaserfilter #Silicagelröhrchen #[1 #air analyses #biphenylol #hazardous substances #high-performance liquid chromatography #o-Phenylphenat #o-Phenylphenol #o-phenylphenol #orthophenylphenol #quartz fiber filter #silica gel sorbent tube #vapour particle mixture #workplace measurement
paper · doi:10.34865/am9043d6_4or
This analytical method is a validated measurement procedure for the determination of o-phenylphenol [90-43-7] in workplace air in a concentration range of one tenth up to twice the currently valid occupational exposure limit in Germany of 5 mg/m3. For sampling a defined volume of air is drawn through a binder-free quartz fibre filter followed by a silica gel sorbent tube. The flow rate is set to 1 l/min and sampling duration is 2 hours (which correspond to a sampling volume of 120 l). o-Phenylphenol is extracted with 2-propanol and subsequently analysed using liquid chromatography with diode array detection. The quantitative determination is based on a calibration function. The limit of quantification is 0.0183 mg/m3 based on an air sample volume of 120 l. The mean recovery is 94% and the expanded uncertainty for the validation range of 0.5 to 10 mg/m3 is 27 to 30%.