vix.ing · top · new · best · stats · spec

A study of silicon sensor for ILD ECAL

2014/03/31 by Tatsuhiko Tomita, Tomita, Tatsuhiko, S. Chen +21
Physics and Astronomy · #Dark Matter and Cosmic Phenomena #FOS: Physical sciences #Instrumentation and Detectors (physics.ins-det) #Particle Detector Development and Performance #Particle physics theoretical and experimental studies

paper · pdf · doi:10.48550/arxiv.1403.7953

openalex publication_date 2014/03/31 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28

Abstract

The International Large Detector (ILD) is a proposed detector for the International Linear Collider (ILC). It has been designed to achieve an excellent jet energy resolution by using Particle Flow Algorithms (PFA), which rely on the ability to separate nearby particles within jets. PFA requires calorimeters with high granularity. The ILD Electromagnetic Calorimeter (ECAL) is a sampling calorimeter with thirty tungsten absorber layers. The total thickness of this ECAL is about 24 X0, and it has between 10 and 100 million channels to make high granularity. Silicon sensors are a candidate technology for the sensitive layers of this ECAL. Present prototypes of these sensors have 256 5.5×5.5 mm2 pixels in an area of 9×9 cm2.We have measured various properties of these prototype sensors: the leakage current, capacitance, and full depletion voltage. We have also examined the response to an infrared laser to understand the sensor's response at its edge and between pixel readout pads, as well the effect of different guard ring designs. In this paper, we show results from these measurements and discuss future works.

Related