vix.ing · top · new · best · stats

Integrated anti-electronics for positron annihilation spectroscopy

2024/02/02 by Guatieri, Francesco
#FOS: Physical sciences #Instrumentation and Detectors (physics.ins-det)

paper · doi:10.48550/arxiv.2402.01307

Abstract

Imaging the features of a sample using Positron Annihilation Spectroscopy (PAS) is currently achieved by rastering, i.e. by scanning the sample surface with a sharply focused positron beam. However, a beam of arbitrary shape (sculpted beam) would allow the application of more versatile single-pixel imaging (SPI) techniques. I introduce the design of a microelectronic device employing a 2D array of Zener diodes as an active positron moderator, capable of sculpting positron beams with 6um resolution. The re-emitted positrons are accelerated towards the sample through a miniaturised electrostatic lens system and reaching 100nm resolution. The fast switch-on (90ps) and switch-off (250ps) time of the device would enable state-of-the-art positron annihilation lifetime spectroscopy (PALS) and PAS imaging with high spatial and temporal resolution.

Related