vix.ing · top · new · best · stats · spec

A prospective, randomized trial of rifampicin-minocycline-coated and silver-platinum-carbon-impregnated central venous catheters*

2006/02/22 by David J. Fraenkel, David Fraenkel, Claire Rickard +6
Health Professions · Medicine · #Central Venous Catheters and Hemodialysis #Infection Control in Healthcare #Nosocomial Infections in ICU

paper · doi:10.1097/01.ccm.0000201404.05523.34

openalex publication_date 2006/02/22 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/30

Abstract

OBJECTIVE: Central venous catheters are the predominant cause of nosocomial bacteremia; however, the effectiveness of different antimicrobial central venous catheters remains uncertain. We compared the infection rate of silver-platinum-carbon (SPC)-impregnated catheters with rifampicin-minocycline (RM)-coated catheters. DESIGN: A large, single-center, prospective randomized study. SETTING: Twenty-two-bed adult general intensive care unit in a large tertiary metropolitan hospital in Brisbane, Australia (2000-2001). PATIENTS: Consecutive series of all central venous catheterizations in intensive care unit patients. INTERVENTIONS: Randomization, concealment, and blinding were carefully performed. Catheter insertion and care were performed according to published guidelines. Blood cultures were taken at central venous catheter removal, and catheter-tip cultures were performed by both roll-plate and sonication techniques. Pulsed field gel electrophoresis was used to establish shared clonal origin for matched isolates. MEASUREMENTS AND MAIN RESULTS: Central venous catheter colonization and catheter-related bloodstream infection were determined with a blinded technique using the evaluation of the extensive microbiological and clinical data collected and a rigorous classification system. Six hundred forty-six central venous catheters (RM 319, SPC 327) were inserted, and 574 (89%) were microbiologically evaluable. Colonization rates were lower for the RM catheters than SPC catheters (25 of 280, 8.9%; 43 of 294, 14.6%; p=.039). A Kaplan-Meier analysis that included catheter time in situ did not quite achieve statistical significance (p=.055). Catheter-related bloodstream infection was infrequent for both catheter-types (RM 4, 1.4%; SPC 5, 1.7%). CONCLUSIONS: The SPC catheter is a clinically effective antimicrobial catheter; however, the RM catheter had a lower colonization rate. Both catheter types had low rates of catheter-related bloodstream infection. These results indicate that future studies will require similar rigorous methodology and thousands of central venous catheters to demonstrate differences in catheter-related bloodstream infection rates.

Citations

Related