vix.ing · top · new · best · stats · spec

Beam Position Monitor Electronics Upgrade for Fermilab Switchyard

2015/02/05 by Pierpaolo Stabile, John Diamond, Stabile, P. +11
Engineering · Physics and Astronomy · #Accelerator Physics (physics.acc-ph) #FOS: Physical sciences #Gyrotron and Vacuum Electronics Research #Instrumentation and Detectors (physics.ins-det) #Particle Accelerators and Free-Electron Lasers #Particle accelerators and beam dynamics

paper · pdf · doi:10.48550/arxiv.1502.01745

openalex publication_date 2015/02/05 · openalex created_date 2025/10/10 · openalex updated_date 2026/07/28

Abstract

The beam position monitor (BPM) system for Fermilab Switchyard (SY) provides the position, intensity and integrated intensity of the 53.10348 MHz RF bunched resonant extracted beam from the Main Injector over 4 seconds of spill. The total beam intensity varies from 1x1011 to 1x1013 protons. The spill is measured by stripline beam postion monitors and resonant circuit. The BPMs have an external resonant circuit tuned to 53.10348 MHz. The corresponding voltage signal out of the BPM has been estimated to be between -110 dBm and -80 dBm.

Related